Welcome to the Questar III BOCES SafeSchools SDS management system!

Danger

EFFECTIVE DATE

2015-01-12

PICTOGRAMS

HMIS

HEALTH

2

FLAMMABILITY

4

PHYSICAL HAZARD

2

PERSONAL PROTECTION

NFPA

0

4

2

QUESTAR III BOCES & COMPONENT DISTRICTS
Local data

SKU #

*This local data is shared by all revisions

Praxair Acetylene, dissolved

Danger 2015-01-12

Hazard Statements

H220- EXTREMELY FLAMMABLE GAS

H231-MAY REACT EXPLOSIVELY EVEN IN THE ABSENCE OF AIR AT ELEVATED PRESSURE AND/OR TEMPERATURE

H280- CONTAINS GAS UNDER PRESSURE; MAY EXPLODE IF HEATED

OSHA-H01-MAY DISPLACE OXYGEN AND CAUSE RAPID SUFFOCATION

CGA-HG04-MAY FORM EXPLOSIVE MIXTURES WITH AIR.

Precautionary Statements

P202 - Do not handle until all safety precautions have been read and understood

P210 - Keep away from Heat, Open flames, Sparks, Hot surfaces. No smoking

P271 + P403 - Use and store only outdoors or in a well-ventilated place

P377 - Leaking gas fire; Do not extinguish, unless leak can be stopped safely

P381 - Eliminate all ignition sources if safe to do so.

P501 - Dispose of contents/Container in accordinance with container Supplier/owner instructions

CGA-PG05 - Use a back flow preventive device in the piping

CGA-PG13 - Fusible plugs in the top, bottom, or valve melt at 98 degrees C to 107 degrees C (208 degrees F to 224 degrees F).

Do not discharge at pressures above 15 psig (103 kPa)

CGA-PG06 - Close valve after each use and when empty

Manufacturer information

Name

Praxair Inc

Phone

1-800-772-9247

Address

39 Old Ridgebury Road
Danbury, CT 06810

PICTOGRAMS

HMIS

HEALTH

2

FLAMMABILITY

4

PHYSICAL HAZARD

2

PERSONAL PROTECTION

NFPA

0

4

2

QUESTAR III BOCES & COMPONENT DISTRICTS
Local data

SKU #

*This local data is shared by all revisions