Welcome to the Questar III BOCES SafeSchools SDS management system!

Warning

EFFECTIVE DATE

2015-01-07

QUESTAR III BOCES & COMPONENT DISTRICTS
Local data

SKU #

*This local data is shared by all revisions

ATOMIZED ALUMINUM POWDER

Warning 2015-01-07

Hazard Statements

May form combustible dust concentrations in air.

Precautionary Statements

Care should be taken during bulk handling to prevent accumulation/generation over time of 75 micron or finer particles. Use only non-sparking tools and natural bristle brushes. Keep away from heat/sparks/open flames/hot surfaces - No smoking. Ground/bond container and receiving equipment. Use explosion-proof electrical/ventilating/lighting equipment. Prevent dust accumulation to minimize explosion hazard. Take precautionary measures against static discharge

In case of fire: Use appropriate media for extinction

Store in a dry place and/or in closed container. Keep away from heat, sparks and open flame - No smoking. Do not allow chips, fines or dust to contact water, particularly in enclosed areas.

Reuse or recycle material whenever possible. Material that cannot be reused may be sent to a metals reclamation facility that is able to handle fines. Waste material that cannot be reclaimed for metal value should be rendered non-reactive prior to disposal.

Manufacturer information

Name

Alcoa Inc.

Phone

CHEMTREC: +l 703 527 3887

Address

201 Isabella Street
Pittsburgh, PA 15212-5858

QUESTAR III BOCES & COMPONENT DISTRICTS
Local data

SKU #

*This local data is shared by all revisions